Electrical equipment and automatics for pump station. EOiA-NU-ShN
982 560 RUB
Ask a Question
EOiA-NU-ShN
Electrical equipment and automatics for pump station.
Delivery time is 12 weeksCommisioning is required
More details
Need a consultation?
Our experts will answer any question.
Ask a Question
Description
The laboratory stand is intended for teaching students of various specialties studying the disciplines "Electrical machines", "Electrical machines and the fundamentals of an electric drive", "Fundamentals of an electric drive", "Theory of an electric drive", "Automated electric drive", "Control systems for electric drives", "Automation of technological processes and complexes "," Program control systems "," Elements of automation systems".
- Study of Frequency Converter-Asynchro Motor system based on Danfoss VLT® HVAC Drive Fc102 frequency converter:
- Reset to default for Danfoss VLT® HVAC Drive FC102;
- Quick put into operation for Danfoss VLT® HVAC Drive FC102 with the use of LCP;
- Study of open from the point of speed FC-AM system (adjustment of open loop);
- Study of closed from the point of pressure FC-AM system (adjustment of closed loop);
- Configuring Danfoss VLT® HVAC Drive FC102 with the help of MCT 10 Set-up Software;
- Making characteristics records in the graphical panel of LCP and further transfer of characteristics;
- Oscilographic testing for transient processes in FC-AM system with the help of MCT 10 Set-up Software.
- Study of FC-AM system based on Danfoss VLT® AQUA Drive Fc202 frequency converter:
- Reset to default for Danfoss VLT® AQUA Drive FC202;
- Quick put into operation for Danfoss VLT® AQUA Drive FC202 with the help of LCP;
- Study of open from the point of speed FC-AM system (adjustment of open loop);
- Study of closed from the point of pressure FC-AM system (adjustment of closed loop);
- Making characteristics records in the graphical panel of LCP and further transfer of characteristics;
- Configuring Danfoss VLT® AQUA Drive FC202 with the help of MCT 10 Set-up Software;
- Oscilographic testing for transient processes in FC-AM system with the help of MCT 10 Set-up Software.
- Determination of pump head characteristics.
- Study of pipeline characteristics.
- Study of pump characteristics when two pumps connected in parallel.
- Study of pressure relay.
- Study of closed from the point of pressure water supply system.
- Adjustment of cascade controller. Pumps operated in cascade mode.
- Adjustment of Standby mode for a drive with pressure feedback.
- Adjustment of interleaving mode for pumps to provide equal distribution of motors’ resources.
- Study of dry run protection.
- Control cabinet consists of:
- Soft starter;
- Frequency converter (2 pcs.);
- Set of switching and protecting equipment.
- Pump station simulator with equipment installed including:
- Tank, 60 L;
- Backup tank, 60 L;
- Centrifugal pump (2 pcs.);
- Area flow meter (2 pcs.);
- Balance valve;
- Manometers (3 pcs.);
- Pressure gauge, electromagnetic flow meter, pressure relay, float level sensor;
- Pipeline with valves, filters and air discharge valve.
Specifications
Design style | wiring cabinet performance |
Type of control | with laptop |
Dimensions, mm | 3000х1800х650 |
Weight, kg | 250 |
Voltage, V | 3х380 |
Power consumption, VA | 1500 |
Documents