Thermal Power Plant Model with automatic control system. MTES-SK
1 041 180 RUB
Ask a Question
MTES-SK
Thermal Power Plant Model with automatic control system. Stand design with computer
Delivery time is 8 weeks.
Commisioning is advisable
Thermal Power Plant Model with automatic control system. Stand design with computer
Delivery time is 8 weeks.
Commisioning is advisable
More details
Need a consultation?
Our experts will answer any question.
Ask a Question
Description
Laboratory bench allows you to perform laboratory work on the normal and emergency modes of operation of power plants, research on the operation of automatic control systems of the technological and electrical parts of a power plant, the use of freely programmable microprocessor control tools to automate the technological process of generating electric energy, research on the operation of relay protection devices.
Modes of operation of power plants
- Study of the autonomous mode of operation of the power plant on the allocated load.
- Study of the parallel operation mode of the power plant with the network.
- Determination of angle characteristics of synchro generator.
- Study of static stability of power unit at close short circuits.
- Study of static stability of power unit when the electrical load changes.
- Study of PLC:
- Programming in LD language;
- use of timers;
- use of meters;
- basics of analog signals.
- Basics of SCADA system operation:
- study of graphical control options and indications of programming
- environment;
- study of communication principles between bridging devices and an object based on PLC as an example;
- Control systems integration.
- Automatic adjustment of speed of turbogenerator.
- Automatic adjustment of power of turbogenerator.
- Automatic adjustment of speed and power of power plant.
- Automatic adjustment of excitation of synchro generator.
- Automatic synchronization of generator and network.
- Automation of stability control.
- Automatic elimination of asynchronous operation.
- Automatic frequency unloading.
- Current cutoff.
- Overcurrent protection of electricity transmission line with independent time delay.
- Overcurrent protection of electricity transmission line with voltage triggering.
- Protection from single-phase-to-ground short circuit.
- Differential protection of power transformer.
- Differential protection of generator-transformer unit.
- Modules of: Power supply; Three-phase circuit; Speed meter; Excitation; Model of turbogenerator; Power transformer (2 pcs.); Power line; модели Machine load; Switch Synchronization; Switch module of cable electricity transmission line (2 pcs.); Measuring; I/O; Active load; Short circuit switch; Power supply (single-phase); PLC; discrete I/O.
- Electrical machine unit (servomotor, multipurpose AC machine, servodrive, speed sensor).
- Electrical machine unit (asynchro motor, DC motor).
- PC.
- Laboratory table.
- Laboratory rack.
- Desk for PC.
- Bed-side table.
- Software.
- Set of connecting cables.
- Technical description.
- Methodology instructions on how to perform the laboratory works.
Specifications
Design style | stand design |
Type of control | with computer |
Dimensions, mm | 2340х2050х650 |
Weight, kg | 300 |
Voltage, V | 3х380 |
Power consumption, VA | 750 |