System of automatic temperature management. SAU-T-SK
656 190 RUB
Ask a Question
SAU-T-SK
System of automatic temperature management. Laboratory module has stand design with computer.
Delivery time is 10 weeks.
Commisioning is required.
System of automatic temperature management. Laboratory module has stand design with computer.
Delivery time is 10 weeks.
Commisioning is required.
More details
Need a consultation?
Our experts will answer any question.
Ask a Question
Description
Laboratory stand is dedicated for study of primary temperature transducers, industrial data transfer protocols, for students of electrotechnical and technological specialities by courses of automation for technological processes.
Section «Systems of automatic management»
- Study of characteristics for temperature sensors includes:
- static characteristics for thermocouples and thermoresistance;
- dynamical characteristics of thermocouples and thermoresistance.
- Study of automatic regulation includes
- study of specialized meter-regulator (two-positioning and PID-regulation);
- study of PID-regulator on the base of programming logical controller.
- Study of programming logical controller includes
- creation of programs with relay contact scheme language;
- timers usage;
- counters usage;
- basics of analog signals.
- Basics of SCADA-system include
- study of graphical control and indicators of development environment;
- study of connection principles for device pairing with the object as PLK example;
- synthesis of complex management systems with the use of SCADA-system, programming logical controller, PID-regulator and sensors.
-
1.Study of characteristics for typical dynamic elements.
2.Synthesis of systems with sequential connection of elements.
3.Synthesis of systems with parallel connection of elements.
4.Synthesis of systems with counter parallel connection of elements.
5.Sequantial correction of systems for automatic management.
6.Counter parallel correction of systems for automatic management.
7.Parallel correction of systems for automatic management.
8.Study of model with simplest electromechanical system.
- Modules include
- power supply;
- programming logical controller S7-1200;
- temperature controller.
- Air capacity with heater and fan.
- Thermocouple (HK-type).
- Thermocouple (HA-type).
- Bimetallic point thermometer.
- Copper resistance thermometer.
- Platinum resistance thermometer.
- Mono block «Basics of automatic management».
- PC.
- Laboratory table.
- Software (compact disc).
- Sets of power cables and connecting wires.
- Technical description.
- Methodical instructions for laboratory works.
Specifications
Design style | stand design |
Type of control | with computer |
Dimensions, mm | 1200х1550х700 |
Weight, kg | 90 |
Voltage, V | 220 |
Power consumption, VA | 650 |
Documents